SourcingAI

Led emergency ceiling light

I have found results from30000+products and10000+suppliers aboutLed emergency ceiling light

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Recessed
Color Temperature: Pure White
Lamp Body Material: Plastic
Style: European
Shape: Round
Shade Type: Plastic
Usage: Room
IP Rating: IP66
Install Style: Surface Mounted
Certification: CCC
Voltage: 220V
Bulb Type: LED
Emitting Color: White
Light Source: LED
Housing Material: Acrylic
Dimmable: With Dimmable
Appearance: Square
Base Material: Metal
Beam Angle: 120°
Power: 5W
Installation: Recessed
Battery Type: Ni-Cd
Irradiated Area: 5-10m²
Switch Type: Inductive Switch
Emergency Time: 3-4h
Operation Mode: Maintained
Material: Plastic
Cover Material: Plastic
Without Light Source
Applicable Places: Washroom
Folded: Unfolded
Input Voltage: 220V
Source Number: Single Plug
Lamp Installation: Plug Lamp
Warranty: 2 Years
Application: Home Furnishing
Source Color: White
Crust Color: Black
Single Operating Light
Color Temperature: Warm White
Color Temperature: Cool White
Lamp Body Material: ABS
Lamp Body Material: Metal
Modern simplism style
Shape: Square
Usage: Study
Usage: Restaurant
Usage: Aisle
Usage: living room
Usage: balcony
Usage: TOILET
Usage: Kitchen
Usage: Conference Room
Usage: Fire Lights
IP Rating: IP65
IP Rating: IP54
Certification: CE
Certification: CQC
Certification: C-tick
Certification: EMC
Certification: ETL
Certification: FDA
Certification: GS
Certification: LVD
Certification: REACH
Certification: RoHS
Certification: SAA
Certification: ISO9001
Certification: SASO
Certification: VDE
Certification: UL
Certification: ISO13485
Voltage: 85V-265V
Emitting Color: Cool White
Housing Material: Aluminium
Housing Material: Plastic
Housing Material: Glass
Housing Material: PMMA
Housing Material: ABS
Base Material: Plastic
Beam Angle: 60°
Installation: Wall-hanging
Battery Type: Ni-Cd Battery
Battery Type: Rechargeable Battery
Switch Type: Knob Switch
Switch Type: Push-button Switch
Operation Mode: Non-maintained
Cold Rolled Steel Sheet

Sourcing guidance for Led Emergency Ceiling Light

What are the critical technical specifications for LED Emergency Ceiling Lights?

When sourcing, prioritize Lumen Output in emergency mode, which is typically lower than standard mode; ensure it meets local safety codes (e.g., at least 10-15% of normal brightness). The Battery Type is crucial—LiFePO4 (Lithium Iron Phosphate) is preferred over Ni-Cd due to its longer lifespan (5-8 years) and better thermal stability. Additionally, verify the Emergency Duration, which must be a minimum of 90 to 180 minutes depending on regional fire safety regulations.

Which compliance standards and certifications are mandatory for international markets?

For the US market, UL 924 (Emergency Lighting and Power Equipment) is the gold standard. For Europe, look for CE-LVD, CE-EMC, and EN 60598-2-22, which specifically covers emergency luminaires. If you are selling in the UK, UKCA marking is now required. Ensure the supplier provides a valid Test Report from a recognized third-party lab (like TUV, SGS, or Intertek) rather than just a self-declaration.

How do I evaluate the 'Smart' features and maintenance efficiency of these lights?

Modern B2B buyers should look for Self-Test Functionality (ATS), which automatically performs monthly and annual battery discharge tests, reducing manual labor costs. Check for Integrated Microwave Sensors that allow the light to function as a standard motion-sensor light while maintaining emergency readiness. For large-scale projects, confirm if the drivers are DALI-compatible for centralized building management system integration.

What housing materials are best for durability and safety?

The housing should be made of Flame-Retardant Polycarbonate (PC) with a UL94 V-0 rating to prevent the spread of fire. For industrial or outdoor settings, ensure an IP65 rating for dust and water resistance and an IK08 or higher impact rating to protect against vandalism or accidental damage.

Cross-Border Procurement & Risk Management for Emergency Lighting

What are the specific risks associated with shipping LED lights with batteries?

Emergency lights contain batteries, which are classified as Dangerous Goods (UN3481 or UN3480). You must ensure the supplier provides a UN38.3 Test Report and an MSDS (Material Safety Data Sheet). Failure to provide these will lead to customs seizures or rejection by airlines. For sea freight, ensure the batteries are installed inside the equipment to simplify the shipping classification.

How can I verify the reliability of a supplier on Made-in-China.com?

Focus on Audited Suppliers who have undergone on-site inspections by third-party agencies. Check their 'Business Type'—prioritize Manufacturers over Trading Companies for better technical support. Review their Export Experience to your specific country; a supplier familiar with your local voltage (e.g., 110V vs 230V) and certification needs will significantly reduce the risk of receiving non-compliant goods.

What negotiation strategies should be used for bulk emergency lighting orders?

Don't just negotiate on the unit price; negotiate on the Warranty Terms and Component Quality. Ask for a 3 to 5-year warranty that covers both the LED driver and the battery. Request a 2% spare parts allowance (extra drivers or batteries) to be included in the shipment to handle immediate RMAs without waiting for international shipping.

How do I ensure transaction security and quality control before final payment?

Use Secured Payment services provided by Made-in-China.com to ensure funds are only released upon proof of shipment. Always hire a Third-Party Inspection service to conduct a Pre-Shipment Inspection (PSI). The inspector should specifically test the 'Switch-over time' (should be <1 second) and the actual battery discharge duration to ensure they match the advertised specifications.

Related queries