Metal halide bulb
I have found results from9000+products and2000+suppliers aboutMetal halide bulb
HoneyFly G12 PGZ18 Ceramic Metal Halide Bulb 220V 315W CMH Grow
HoneyFly Metal Halide Bulb MSR HTI 700W Easylock Mini Fast Fit PGJX50
High Power Quartz Fish Luring Metal Halide Bulb for Offshore Squid Fishing Vessel, E40 Base
Metal Halide Deep Sea Fishing Lamp Bulb for Offshore Squid Fishing Vessel, E40 Base
CE High Efficiency Cdm-R Ceramic Metal Halide Lamp Rx7s CMH Bulb
CE Quartz Tubular CMH Elliptical Ceramic Metal Halide Bulb
1200W/SA Stage Studio Lamp Metal Halide Bulbs Replacement Msr 1200SA Gy22
260W Beam Lamp 9r UHP Bulbs Dage Acme Beam Moving Head Spot
Replacement for HQI Ts 2000W/D/S Metal Halide Light Bulb
250W Harmony Metal Halide Bulb About Jqd-250, Jqd-400, Jjq250, Jjq400
Colshine 36W LED Corn Bulb, LED Corn Light, E26 Medium Base, 4500lumens, Replace 150-175W Metal Halide Bulb, 5000K
Outdoor Garden Park Square Clear Glass Metal Halide Bulb
Clear Glass High Intensity Discharge Standard Metal Halide Bulb
Long Life Anti-Explosion Coated Elliptical Metal Halide Bulb
Plant Grow Light Mixture Metal Halide Bulb Mh 250W/ 400W /1000W
Beam Light Stage Metal Halide Lamp Msd200 R5 200W Bulb
Railway High-Speed Locomotive Metal Halide Bakelite Base Bulb
Sourcing guidance for Metal Halide Bulb
What are the key technical specifications to consider when sourcing Metal Halide Bulbs?
Buyers must prioritize Luminous Efficacy (lm/W), typically ranging from 75 to 100 lm/W, and Color Rendering Index (CRI), which should be above 65 for industrial use and above 85 for retail displays. Ensure the Color Temperature (CCT) aligns with the application: 3000K-4200K for warm/neutral environments or 5000K-6500K for daylight simulation. Additionally, verify the Rated Average Life, which should exceed 10,000 to 20,000 hours to minimize maintenance costs.
Which international compliance standards are mandatory for Metal Halide Bulbs?
For the North American market, bulbs must be UL or ETL listed and comply with ANSI standards (e.g., M59, M132) to ensure ballast compatibility. For the European market, CE marking and RoHS compliance are mandatory to restrict hazardous substances like mercury. Furthermore, check for IEC 61167 performance standards to ensure global interchangeability and safety.
How do I ensure the physical safety and explosion-proof capabilities of these bulbs?
Metal Halide Bulbs operate under high pressure and temperature. You should specify 'O' rated (Open Luminaire) bulbs which include a protective quartz shroud to prevent the outer envelope from shattering in the event of an arc tube rupture. For enclosed fixtures, 'E' rated bulbs are acceptable. Always request thermal shock resistance test reports for the outer glass envelope.
What are the common usage scenarios and ballast compatibility requirements?
These bulbs are primarily used in high-bay warehousing, stadium lighting, and horticulture (HID grow lights). It is critical to match the bulb to the ballast type (Magnetic vs. Electronic). Using a bulb with an incompatible ballast can lead to premature failure, flickering, or color shifting. Always confirm the Start Type (Pulse Start vs. Probe Start) with the supplier before finalizing the purchase.
Cross-Border Procurement & Risk Management for Lighting Equipment
What are the primary risks when shipping Metal Halide Bulbs internationally?
The biggest risk is fragility and hazardous material classification. Because these bulbs contain small amounts of Mercury (Hg), they may be subject to specific customs declarations and environmental regulations. Ensure the supplier uses double-walled corrugated packaging with EPE foam inserts to prevent breakage during sea or air transit, as a breakage rate above 3% significantly impacts profit margins.
How should I negotiate quality assurance and defect rates with Chinese suppliers?
When sourcing via Made-in-China.com, negotiate a Defective Goods Allowance (DGA). A standard industry acceptable defect rate is below 1%. Demand a 2-year warranty and stipulate that the supplier must provide 1-2% extra units (FOC - Free of Charge) with the bulk shipment to cover potential transit damage or early-life failures.
What transaction security measures should be taken for large B2B lighting orders?
Utilize Secured Trading Services offered by platforms like Made-in-China.com to ensure payment is only released upon proof of shipment. For large orders, hire a third-party inspection agency (like SGS or Intertek) to perform a Pre-Shipment Inspection (PSI) to verify the quantity, CCT consistency, and vacuum seal integrity before the final balance is paid.
How do international trade policies affect the import of HID lamps?
Be aware of the Minamata Convention on Mercury, which aims to phase out mercury-added products. Some regions have high anti-dumping duties or specific energy efficiency labels (like EU Energy Label A-G). Always verify the HS Code (typically 8539.32) with your local customs broker to calculate accurate import duties and VAT before placing the order.