Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Swing Gate
Type: Wing Gate
Type: Revolving
Type: Sliding gate
Sensing Method: Electric
Access Control System
Movement: Single Movement
Control Mode: Semi-Automatic
Communication Interface: RS485
Material: Steel
Style: Modern
Sound Insulation: 45
Position: Exterior
Security Rating: C
Surface Finishing: Finished
Function: Security
Condition: New
Color: Brown
Customized: Customized
Certification: CE
Open Style: Revolving
Opening Type: Induced
Special Function: Security
Fully Insulated Doorsets
Application: Cable Well
Application: Discharge Flue
Application: Elevator Room
Application: Stairway
Movement: Double Movement
Control Mode: Automatic
Communication Interface: TCP/IP
Material: Aluminum Alloy
Material: Steely
Style: Antique
Style: Simple
Style: Chinese
Style: American
Position: Commercial
Certification: ISO9001
Certification: TUV
Certification: CCC
Open Style: Swing
With Remote Control

Sourcing guidance for Metro Station Door

What are the key technical specifications to consider when sourcing Metro Station Doors?

When procuring Platform Screen Doors (PSD), you must prioritize structural integrity and drive system reliability. Key specs include DC brushless motor drives for smooth operation, toughened safety glass (10-12mm) meeting EN 12150 standards, and a minimum MTBF (Mean Time Between Failures) of 1,000,000 cycles. Ensure the frames are made of 304 or 316L stainless steel or anodized aluminum alloy to resist corrosion in underground environments.

Which international compliance standards are mandatory for metro safety systems?

Safety is paramount. The doors must comply with SIL (Safety Integrity Level) 2 or 3 according to EN 50126/50128/50129 standards. Additionally, verify fire resistance ratings (typically 30-60 minutes) and electromagnetic compatibility (EMC) to ensure the door electronics do not interfere with train signaling systems. For the North American market, UL certifications for electrical components are essential.

How do I ensure the doors are compatible with different train signaling systems?

You must confirm that the Door Control Unit (DCU) supports standard communication protocols such as CANbus, RS485, or Ethernet/IP. The supplier should provide interface documentation to ensure seamless integration with the ATC (Automatic Train Control) and ATO (Automatic Train Operation) systems. Requesting a protocol compatibility test report during the sourcing phase is highly recommended.

What are the different types of metro doors based on station environment?

There are three main types: Full-Height PSDs, which completely seal the platform from the track (ideal for HVAC energy saving); Half-Height Automatic Platform Gates (APG), used for above-ground stations to prevent falls; and Emergency Exit Doors (EED), which must feature manual override mechanical locks that allow passengers to open them from the track side without power.

Cross-Border Procurement & Risk Management for Metro Systems

What are the primary risks when importing heavy infrastructure components like station doors?

The biggest risks are logistical damage and technical misalignment. Due to the size and weight, use reinforced sea-worthy wooden crates and specify FOB or CIF terms that include comprehensive marine insurance. To mitigate technical risks, utilize Made-in-China.com's Secured Trading Service to ensure payment is only released after third-party pre-shipment inspection (PSI) confirms the dimensions and functions match your blueprints.

How should I negotiate with suppliers regarding long-term maintenance and parts?

Metro projects last decades, so negotiate a guaranteed spare parts availability for 10-15 years. Demand a 2-5% 'warranty bond' or holdback payment until the commissioning phase is successful. Ask for on-site installation supervision and technical training for local staff to be included in the contract price.

What shipping methods are recommended for oversized metro door panels?

For large-scale station renovations, 40ft Open Top (OT) or Flat Rack (FR) containers are necessary for top-loading the heavy glass and frame assemblies. Ensure the supplier provides a detailed loading plan to prevent glass breakage. For urgent electronic components (DCUs/Sensors), air freight is viable, but the main structures should always be moved via ocean freight to manage costs.

How can I verify the credibility of a Chinese manufacturer for high-stakes public infrastructure?

Look for 'Audited Suppliers' on Made-in-China.com who hold ISO 3834 (Welding Quality) and IRIS (International Railway Industry Standard) certifications. Review their past project portfolio, specifically looking for previous exports to government-run transit authorities, and request factory video audits to inspect their CNC machining and assembly lines.