SourcingAI

Negative ion generator ionizer

I have found results from3000+products and700+suppliers aboutNegative ion generator ionizer

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Electrolytic Type
Type: Electrostatic
Type: HEPA Filter
Negative Ion Generator
Air Handling Unit
Type: Anion
Type: Ozone
Certification: RoHS
Dielectric Material: Ceramic Plate
Cooling Method: Air-Cooling
Gas: Air
Frequency: 50-60Hz
Installation: Portable
Customized: Non-Customized
Condition: New
Tilted: Non-Tilted
Folded: Non-Folding
Using Ambient: Indoor
Power Supply: Electric-Powered
Color: White
Material: Plastic
Structure: Portable
Usage: Home
Air Volume: <50m³/h
Power Source: AC Source
Active + Passive
Purifying Technology: Ozone
Anion Density: 1000000pcs/m³
Application Area: >61m²
Application: Car
Mute indicator: <40dB(A)
Air Tube Material: Plastics
Corrosion Durability: Higher
Noise Level: Low
Application Fields: Mine
Mounting: Ceiling Mount
Lifetime: 5~10 years
Certification: CE
Certification: ISO
Certification: UL
Certification: CQC
Certification: ETL
Certification: ROHS
Certification: GS
CE / EU
Certification: MSDS
Certification: CSA
Power Supply: Ignitor
Structure: Floor Standing
Structure: Ceiling
Central Air Conditioners
Usage: Industry
Usage: Car
Usage: Medical
Usage: Engineering
Air Volume: >400m³/h
Air Volume: 151-300m³/h
Air Volume: 51-150m³/h
Power Source: Electrical
Power Source: USB
Operating Principle: Active
Operating Principle: Passive
Purifying Technology: HEPA
Purifying Technology: Air Ionizer
Purifying Technology: UV
Anion Density: >4000000pcs/m³
Anion Density: 2500000pcs/m³
Anion Density: 2000000pcs/m³
Anion Density: 500000pcs/m³
Anion Density: 3000000pcs/m³
Application Area: 41-60m²
Application Area: 11-20m²
Application Area: <10m²
Application Area: 21-30m²
Application Area: 31-40m²
Application: Mini Car
Application: Household
Application: Commercial
Application: Industrial

Sourcing guidance for Negative Ion Generator Ionizer

What are the key technical specifications to evaluate when sourcing a Negative Ion Generator?

Buyers must prioritize the Ion Emission Concentration, typically measured in ions/cm³. For effective air purification, a concentration of at least 10 million ions/cm³ at a 10cm distance is standard. Additionally, verify the Ozone Output level; it must be below 0.05 ppm to comply with health safety standards like UL867 or IEC 60335-2-65. Ensure the device uses carbon fiber or stainless steel needles for emission to prevent rapid oxidation and ensure a long service life.

Which compliance certifications are mandatory for international trade of ionizers?

For the US market, EPA registration and CARB (California Air Resources Board) certification are critical for air cleaning devices. For the EU, CE marking (LVD and EMC directives) and RoHS compliance are mandatory to ensure the product is free from hazardous substances. If the unit is intended for medical or high-end wellness environments, look for ISO 13485 or specific Microbial Reduction Rate reports from third-party labs.

How can I assess the durability and performance stability of these devices?

Request a Continuous Operation Test report showing the device can run for 8,000+ hours without a significant drop in ion density. Evaluate the input voltage stability; high-quality units should support a wide range (e.g., 100V-240V AC or 5V/12V DC) with built-in short-circuit and overheat protection. For industrial modules, check the encapsulation material (e.g., epoxy resin) which protects the high-voltage generator from moisture and dust.

What are the typical application scenarios for different types of ionizers?

Sourcing requirements vary by use case: Portable/Wearable units require low power consumption and rechargeable lithium batteries with UN38.3 certification. Home/Office purifiers should focus on CADR (Clean Air Delivery Rate) and low noise levels (<30dB). Industrial/HVAC modules must be designed for easy integration into existing ductwork and feature high-voltage output stability to handle large airflow volumes.

Cross-Border Procurement Risks and Strategic Advice

How can I mitigate the risk of 'Ozone Leakage' in mass-produced units?

Ozone is a common byproduct of ion generation. To mitigate risk, include a clause in your contract requiring batch-testing for ozone emissions. Use Made-in-China.com's inspection services to verify that the production units match the initial samples. High-quality suppliers will use pulsed DC or AC technology to minimize ozone while maximizing negative ion output.

What is the best strategy for negotiating with electronic component suppliers?

Focus on the core component brand (e.g., the high-voltage transformer). Negotiate based on Total Cost of Ownership (TCO) rather than just the unit price. Request a tiered pricing structure where the price drops by 10-15% as volume reaches 5,000 units. Ensure the supplier provides a 1-2 year replacement warranty for the generator module, as this is the most common point of failure.

What are the shipping precautions for ionizers containing batteries or high-voltage parts?

If the ionizers contain built-in batteries, they must be shipped as Class 9 Dangerous Goods or under specific PI966/PI967 regulations. Ensure the supplier provides a Material Safety Data Sheet (MSDS) and a Safe Transport of Goods report. For the high-voltage modules, ensure anti-static packaging (ESD bags) and robust cushioning are used to prevent internal component displacement during sea or air freight.

How do I ensure transaction security when dealing with overseas manufacturers?

Always utilize Secured Trading Services on Made-in-China.com to protect your payments. Do not release full payment until the Pre-Shipment Inspection (PSI) is passed. Verify the supplier's Audit Report on the platform to check their factory size, export experience, and whether they are a Gold Member or Audited Supplier with a proven track record in the electronics industry.

Related queries