Particle counters
I have found results from80000+products and20000+suppliers aboutParticle counters
Dust Particles Analyser Air Quality Detection Particle Counter
Skz1050e OEM Clean Rooms Ust-Free Workshop Laboratory Dust Particle Counter
Portable Indoor Air Quanlity Monitor Dust Particle Counter Pm2.5
Portable Dust Particle Counter Pm2.5 Detector Air Quality Counter
Pm2.5 Detector Particle Counter for Environmental Monitoring Station
Indoor Air Quality Monitor-Dust Particle Counter (PM0.3/0.5/1.0/2.5)
Laser Particle Counter MDS-C68 Built in High-speed Thermal Printer
MDS-CH68(X) RS485 for remote management of cleanroom particle counters
Handheld Laser Dust Particle Counter Particulate Matter Dust Air Quality Monitor
Online High-Speed Particle Counter with Dust Particle Monitor and Data Transmission Device
Remote Online Dust Particle Counter 6-Channel Laser Air Particle Sensor
Handheld Airborne Particle Counter for Cleanroom ISO 14644
Particle Dust Air Particle Counter/Dust Particle Counter
Biobase Particle Counter Clj-2803 Dust Particle Counter High Quality for Lab
Biobase Particle Counter 0.3~10um 28.3L/Min 2.83L/Min Clean Environment Portable
R310 Remote Airborne Particle Counter Sensor for Pharmaceutical
Zetron B330 Portable Airborne Particle Counter for Efficient Dust Monitoring
H630 Handheld Particle Counter for Cleanroom Air Quality Monitoring
Zetron B330 Compact Particle Counter HVAC System Contamination Detection
B1030 High Accuracy Particle Counter for Pharmaceutical Cleanroom Testing
Touch Screen Display Portable Laser Dust Particle Counter
Handheld Dust Pm2.5 Particle Counter Co Nox with Gas Detection
Portable 3 Channel Pm10 Pm2 5 Particle Counter with Laser Sensor
Sourcing guidance for Particle Counters
What are the key technical specifications to consider when selecting a particle counter for industrial use?
When evaluating particle counters, the most critical specification is the sensitivity and channel sizes, typically ranging from 0.3μm to 10μm. For cleanroom applications, ensure the device complies with ISO 14644-1 standards. Additionally, check the flow rate (standard rates are often 0.1 CFM or 1.0 CFM) as it determines how quickly a volume of air can be sampled. For high-concentration environments, prioritize models with a high coincidence loss limit to ensure data accuracy.
How do I ensure the particle counter meets international compliance and calibration standards?
Professional B2B buyers must verify that the equipment meets ISO 21501-4, which is the international standard for light scattering airborne particle counters. Ensure the supplier provides a NIST-traceable calibration certificate. For pharmaceutical or medical device manufacturing, the device must support 21 CFR Part 11 compliance for electronic records and data integrity.
What are the differences between handheld, portable, and remote particle counters in terms of usage scenarios?
Handheld particle counters are ideal for spot-checking and troubleshooting specific areas due to their lightweight design. Portable units offer higher flow rates and larger displays, suitable for formal cleanroom certification. Remote (fixed) sensors are designed for continuous 24/7 monitoring and are usually integrated into a Facility Monitoring System (FMS) via Modbus or Ethernet (PoE).
What maintenance is required to ensure the long-term accuracy of the device?
Particle counters require annual recalibration by a certified laboratory to account for laser diode aging and sensor drift. Users should perform zero-count tests daily using a HEPA filter attachment to ensure there are no internal leaks or sensor contamination. For liquid particle counters, regular flushing with deionized water is essential to prevent cross-contamination.
Cross-Border Procurement & Risk Management for Precision Instruments
What are the primary risks when sourcing high-precision instruments like particle counters internationally?
The main risks include calibration shift during transit due to excessive vibration and customs delays caused by improper HS Code classification. Always request shock-resistant packaging (double-boxing with foam inserts). Ensure the supplier uses the correct HS Code (typically 9027.10) to avoid tariff penalties or seizure by customs authorities.
How can I verify the credibility of a Chinese supplier for technical equipment?
Focus on suppliers listed as Audited Suppliers on Made-in-China.com, as they undergo third-party verification by agencies like SGS or Bureau Veritas. Review their R&D capabilities and check if they hold CE, FCC, or RoHS certifications. Requesting a video factory audit to see their calibration lab in operation is a highly effective way to mitigate quality risks.
What negotiation strategies should be used for bulk orders of particle counters?
Beyond unit price, negotiate for extended warranties (24 months instead of 12) and the inclusion of spare parts like extra batteries or sampling probes. For large-scale projects, request tiered pricing where the cost drops by 10-15% for orders exceeding 10 units. Also, discuss software licensing fees upfront to avoid recurring hidden costs for data management.
What is the safest way to handle payments and shipping for high-value electronic exports?
Use Secured Trading Services provided by Made-in-China.com to ensure funds are only released upon proof of shipment. For shipping, choose Air Freight (DAP or CIP terms) rather than Sea Freight to minimize the time the sensitive laser components are exposed to humidity and temperature fluctuations. Ensure the cargo is covered by All-Risk Insurance.