PDU
I have found results from20000+products and6000+suppliers aboutPDU
6way C13+4way C19 PDU Socket Power Distribution Unit PDU 19′ ′ 1u 250V 16A for Data Centers Server Rooms
8 Way 10A 250V 2500W Fireproof PC Cabinet PDU Power Strip Socket
8 Way 10A Overload Protection Aluminum Alloy Cabinet PDU Power Socket
1u 19 Inch Rack Mount Cabinet Aluminum Alloy Power Distribution Unit PDU
Reliable 20A Hydraulic Breaker with Intelligent PDU Features
Customizable Intelligent PDU for Rackmount Servers
IEC C19 Basic Rack-Mount PDU 6 Outlet with Locking Sockets & Power Indicator
Inlet Monitoring Power Distribution Unit with C13 & C19 Outlets Rack PDU
20-Outlet Vertical Rack PDU: Schuko Outlets, 16A Circuit Breaker Protection for Cabinet
20A 8-Outlet Horizontal Basic Rack PDU with NEMA 5-20r Outlets & Power Indicator
Switched Smart Rack PDU with Remote Per Outlet Control & Inlet Power Metering
16A/4kw IEC C13 Rack-Mount PDU 8-Outlets with Power Indicator for Service Cabinet
13A Smart Metered Vertical Rack PDU: BS1363/UK Outlets, RS485 Remote Monitoring
Le South Africa Network Server Rack 19 Inch PDU Power Distribution Unit
Le 19" Germany Type Rack Power Distribution Unit PDU
IEC Type Power Distribution Unit 1.5u 19-Inch 4-C19+12-C13 Sockets 32A with Switch PDU
Sourcing guidance for PDU
How to choose the right PDU type for different data center environments?
Selecting the correct PDU depends on the level of control required. For basic power distribution, a Basic PDU is sufficient. However, for remote management, you should opt for a Metered PDU (to monitor load levels) or a Switched PDU, which allows for remote outlet toggling to reboot hung equipment. For mission-critical facilities, Automatic Transfer Switches (ATS) PDUs are essential to provide power redundancy to single-corded devices.
What are the key technical specifications to verify for PDU safety and performance?
Buyers must prioritize Input Voltage (110V, 220V, or 3-phase) and Amperage (16A, 32A, etc.) to match the facility's power supply. Ensure the unit features High-grade Flame Retardant PC material and Pure Copper Busbars to minimize heat generation. For high-density racks, verify the Maximum Load Capacity and ensure the PDU includes Integrated Circuit Breakers to prevent overcurrent damage.
Which international compliance standards are mandatory for PDU exports?
Compliance is non-negotiable for electrical safety. For the North American market, UL 60950-1 or UL 62368-1 certification is required. For the European market, look for CE marking, RoHS compliance, and LVD (Low Voltage Directive). If sourcing from Made-in-China.com, ensure the supplier provides valid ISO 9001 quality management certificates and third-party test reports.
How does socket configuration impact PDU usability?
The PDU must match the plugs of your IT equipment. Common international standards include IEC C13 and C19 sockets, which are universal for servers and switches. For regional needs, ensure the PDU supports UK, Schuko, or US NEMA standards. Always calculate the Total Number of Outlets needed, adding a 20% buffer for future expansion.
Cross-Border Purchasing Considerations for PDUs
What are the primary risks when importing PDUs and how to mitigate them?
The biggest risk is Electrical Incompatibility or substandard internal wiring. To mitigate this, request a Pre-shipment Inspection (PSI) to verify internal soldering quality and grounding. Use Secure Payment Terms through platforms like Made-in-China.com to ensure funds are only released after confirming the goods meet the agreed technical specifications.
How to negotiate effectively with PDU manufacturers for bulk orders?
Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for Extended Warranties (3-5 years) and the inclusion of Mounting Accessories (L-brackets or buttons). For orders exceeding 500 units, aim for a 10-15% volume discount and request Custom Branding (OEM) at no additional cost.
What logistics and shipping precautions should be taken for sensitive electrical equipment?
PDUs are sensitive to moisture and physical impact. Insist on Vacuum Sealing or Anti-Static Bagging and the use of Reinforced 5-Layer Corrugated Cartons. For sea freight, ensure the pallets are Fumigated and Shrink-wrapped to prevent salt-air corrosion. Clearly define Incoterms (e.g., FOB or CIF) to establish clear liability boundaries during transit.