SourcingAI

Small water chiller

I have found results from100000+products and40000+suppliers aboutSmall water chiller

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Water-Cooled
Type: Air-Cooled
Piston Refrigeration Machinery
Cooling Method: Water-cooled
Unit Structure: Split
Selected Voltage: 380V/50HZ
Noise Level: Low
Certification: ISO
Condition: New
Application: Cooler
Regenerative Heat Exchanger
Style: Steel Type
Material: Stainless Steel
Compressor Number: 1
Application Fields: Chemical
Application Machine: Machining Center
Customized: Customized
Structure: Portable
Voltage: 220V
Sealing Method: Semi-Closed
Cooling Mode: Air-Cooled
Automatic Grade: Automatic
Power Supply: Electric
Applicable Material: Rubber
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220V/50HZ
Noise Level: Ordinary
Noise Level: Ultra Low
Certification: CE
Certification: CCC
Certification: UL
Certification: RoHS
Certification: UR
Application: Industry
Application: School
Application: Hospital
Application: Lab
Compressor Number: 2
Application Fields: Plastic
Application Fields: Electroplating
Application Fields: Food Processing
Application Fields: Electronic
Precision Machine Tool
CNC Machine Tools
Application Machine: Combination machine
Customized: Non-Customized
Sealing Method: Totally Enclosed
Applicable Material: Plastic

Sourcing guidance for Small Water Chiller

What are the key technical specifications to consider when selecting a small water chiller for industrial or laboratory use?

When sourcing a small water chiller, you must prioritize Cooling Capacity (measured in Watts or BTU/h) to ensure it can handle the heat load of your equipment. Key technical factors include Temperature Stability (ideally ±0.1°C to ±0.5°C) for precision tasks, Pump Lift and Flow Rate to ensure adequate coolant circulation, and the Refrigerant Type (e.g., R-134a or R-410a) which must comply with local environmental regulations. Additionally, check for Tank Capacity to ensure thermal inertia and Noise Levels if the unit will be used in a laboratory setting.

Which international compliance standards and certifications are mandatory for importing water chillers?

For the European market, the CE Marking is essential, specifically compliance with the Machinery Directive (2006/42/EC) and the Low Voltage Directive (2014/35/EU). For the North American market, look for UL or ETL certification. Since these units contain pressurized refrigerants, ensure the supplier provides RoHS compliance for hazardous substances and ISO 9001 certification to guarantee manufacturing consistency and safety.

How can a buyer evaluate the energy efficiency and economic feasibility of a specific chiller model?

Evaluate the Energy Efficiency Ratio (EER); a higher EER indicates lower operational costs over time. Consider units equipped with Inverter Technology, which allows the compressor to adjust its speed based on demand, potentially saving 20-40% in energy consumption. Calculate the Total Cost of Ownership (TCO) by factoring in the initial purchase price, shipping, maintenance intervals, and the availability of low-cost replacement parts like filters and sensors.

What usage scenarios are best suited for 'small' or 'portable' water chillers?

Small water chillers are ideal for CO2 Laser Cutting/Engraving machines, UV Curing systems, Laboratory Spectrometers, and Medical Imaging equipment. They are also widely used in Semiconductor manufacturing for cooling etching tools. Ensure the chiller's Internal Piping Material (e.g., stainless steel or copper) is compatible with the specific fluid used in your application to prevent corrosion.

Cross-Border Procurement & Risk Management for Water Chillers

What are the primary risks when shipping industrial chillers internationally and how can they be mitigated?

The biggest risk is Refrigerant Leakage or Compressor Damage due to vibration during transit. Ensure the supplier uses Reinforced Plywood Crating (not just cardboard) and secures the compressor with Shipping Bolts. Furthermore, verify if the unit is shipped 'Charged' or 'Discharged'; many airlines prohibit pressurized gas, so you may need to refill the refrigerant locally upon arrival, which adds to the setup cost.

How should buyers negotiate with suppliers on Made-in-China.com to ensure quality and transaction security?

Always request a Factory Audit Report or a video walkthrough of the production line. When negotiating, insist on a 30% deposit and 70% balance payment after third-party inspection (such as SGS or Intertek) but before shipment. Use Secured Trading Services provided by the platform to protect your funds. Clearly define the Warranty Terms (minimum 12-24 months) and ensure the supplier agrees to provide Free Spare Parts for any components damaged during the warranty period.

What logistics considerations are specific to shipping heavy machinery like chillers to different regions?

For heavy and sensitive equipment, Sea Freight (LCL or FCL) is the most economical, but ensure the supplier provides a Material Safety Data Sheet (MSDS) for the refrigerant to avoid customs delays. If shipping to the US or EU, confirm the HS Code (typically 8418.69) to calculate accurate import duties. For urgent laboratory needs, Air Freight is possible but requires the refrigerant to be drained to comply with IATA Dangerous Goods Regulations.

Related queries