Spe cartridge
I have found results from500+products and200+suppliers aboutSpe cartridge
Sinter Polyethylene Filter Cartridge for Water Purifier
Sintered Plastic PP/PE Water Filter Cartridge with Factory Customization
Sintered PE Porous Plastic Tube N2 Nitrogen Filter Air/Gas Cartridge
White Sintered Porous Plastic Polyethylene Screw Air Compressor Filter Cartridge
Widely Used PE/PTFE Sintered Filter Cartridge for Waste Water Treatment Industry
1000mg/6ml Hlb Spe Cartridges for Gc LC Sample Preparation in Food Analysis
500mg/6ml Psa Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
60mg/6ml Hlb Spe Cartridges for Gc LC Sample Preparation in Food Analysis
60mg/3ml Wcx Spe Cartridges for Gc LC Sample Preparation in Food Analysis
Wcx 500mg/6ml Spe Cartridges for Gc LC Sample Preparation in Food Analysis
C18 300mg/1ml Spe Cartridges for Gc LC Sample Preparation in Environmental Analysis
Wcx 30mg/1ml Spe Cartridges for Gc LC Sample Preparation in Food Analysis
Customized 1 3 6 12 20 30 60ml Empty Spe Cartridge Solid Phase Extraction Column with Frits
Glass Spe Column Screen Filter Cartridge - Medical and Laboratory Grade
High-Quality Glass Spe Column Filter Cartridge for Labs
Durable Spe Cartridge with Frit and PE Filter for Solid Phase Extraction
Customized 1 3 6 12 20 30 60ml Empty Spe Cartridge Spe Tube Solid Phase Extraction Column with Frits
Kaho Advanced Empty Spe Cartridge for Clean Water Filtration
Kaho Empty Spe Cartridges for Reliable Medical Extraction Processes
High-Quality Empty Spe Cartridge for Medical Applications and Research
Alwsci C18 Solid Phase Extraction Spe Cartridges 3ml 500mg
Alwsci 6ml 500mg C18 Spe Column Cartridge for Laboratory Analysis
Alwsci 3ml 200mg Silica Spe Cartridge for Food Analysis
Sourcing guidance for Spe Cartridge
How to select the correct sorbent material for SPE cartridges?
Choosing the right sorbent is critical for recovery rates. For non-polar compounds, select C18 or C8 bonded silica. For polar analytes in non-polar matrices, Silica, Alumina, or Florisil are preferred. If you are dealing with ionic compounds, utilize Ion Exchange sorbents (SAX, SCX). For broad-spectrum applications, Polymeric sorbents (HLB) offer superior stability across a wide pH range (1-14) and prevent sorbent drying.
What technical specifications ensure high reproducibility in lab results?
B2B buyers should verify the carbon loading percentage (typically 17-19% for C18) and surface area (m²/g). Ensure the particle size is consistent (usually 40-60 μm) to maintain stable flow rates. Additionally, check the pore size (60Å or 100Å) to ensure it matches the molecular weight of your target analytes. High-quality cartridges must use medical-grade polypropylene housings to prevent leachables and extractables from contaminating the sample.
What are the essential compliance and quality standards for SPE products?
Suppliers should ideally hold ISO 9001 certification for manufacturing consistency. For pharmaceutical or clinical applications, look for COA (Certificate of Analysis) for every batch, detailing recovery rate tests and cleanliness verification. Ensure the products meet REACH and RoHS standards if exporting to the EU to confirm the absence of hazardous substances in the plastic housing or frit materials.
How to determine the appropriate cartridge volume and sorbent mass?
The rule of thumb is that the sorbent mass should be at least 5% of the total sample mass for silica-based sorbents. Common sizes include 1mL/100mg, 3mL/500mg, and 6mL/1g. For large volume environmental water samples, 6mL or 12mL cartridges are standard to prevent clogging and ensure adequate residence time for analyte adsorption.
Cross-Border Procurement & Risk Management for SPE Cartridges
How to mitigate quality risks when sourcing SPE cartridges from overseas?
Request pre-shipment samples from a single production lot to conduct a recovery test in your lab. Use Made-in-China.com’s Secured Trading services to ensure payment is only released after the goods pass quality inspections. Always verify the frit material (PE or PTFE), as poor-quality frits can lead to uneven flow or sample bypass.
What are the key negotiation strategies for bulk SPE orders?
Focus on Tiered Pricing; for lab consumables, moving from 1,000 to 10,000 units can often reduce costs by 20-35%. Negotiate for OEM packaging (custom labeling) if you are a distributor. Ask the supplier to provide free replacement units (usually 1-2%) to cover any potential vacuum seal failures during transit.
What logistics and storage precautions should be taken for SPE cartridges?
SPE cartridges are sensitive to humidity and chemical vapors. Ensure the shipping terms specify vacuum-sealed foil packaging to prevent sorbent activation or contamination during sea freight. For shipping to the US or Europe, utilize Air Freight for smaller, high-value batches to maintain a tight supply chain cycle, while Sea Freight (FOB) is more economical for bulk annual stocks.
How to ensure transaction security and trade policy alignment?
Verify the supplier's Audit Report on Made-in-China.com to confirm they are a real manufacturer and not a trading company. Ensure the HS Code (typically 392690 or 382499) is correctly declared to avoid customs delays or incorrect anti-dumping duties in specific regions.