SourcingAI

Test sieve set

I have found results from20000+products and6000+suppliers aboutTest sieve set

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Circular
Type: High Efficiency
Stainless Steel Punching Hole Wire Mesh
Type: Linear
Stainless Steel Plain Wire Mesh
Type: Separating Plant
Sample Type: Solidity
Processing Method: Screening
Warranty: 1 Year
Normal Pressure and Temperature
Display: Digital Display
Performance: Semi-automatic
Weight: 50-100kg
Customized: Non-Customized
High Frequency Vibrating Screen
Transmission Structure: Electromagnetic Shaker
Usage: Mine Shaker
Rotary Vane Shaker
Object: Ore
Circular Vibrating Screen
Condition: New
Shaft Number: Single
Supporting Device: Rubber Spring
Separation Mode: Filter Type
Operating Type: Continuous Type
Installation: Vertical
Centrifuge Type: Tube Centrifuge
Vibration Plate Tower
Pressure: Medium Pressure
Application: Screening
Material: SUS304
Hole Shape: Round
Stainless Steel Wire
Weave Technique: Plain Weave
Wire Mesh Width: 1m
Technique: Perforated
Nickels: 0%
Certification: ISO9001
Maxcapacity: <1000KN
Accuracy Grade: 1
Control: Computer Control
Power Source: AC220V
Warranty: 2 Years
Weight: 0-100Kg
Customized: Customized
Thin Oil Shaker
Transmission Structure: Vibrating Screen
Usage: Experiments Shaker
Lightweight Fine Shaker
Spiral Flash Shaker
Object: Chemicals
Object: Food Processing
Linear Vibrating Screen
Shaft Number: Double
Supporting Device: Coil Spring
Supporting Device: Plate Spring
Pressure: Low Pressure
Application: Filter
Construction Wire Mesh
Application: Protecting Mesh
Application: Screen
Application: Decorative Mesh
Barbecue Wire Mesh
Application: Window Curtain
Application: Fence Mesh
Application: Cages
Stainless Steel Wire
Hole Shape: Square
Technique: Woven
Nickels: 8%

Sourcing guidance for Test Sieve Set

What are the key technical standards to verify when purchasing a test sieve set?

The most critical standards are ASTM E11 (US Standard) and ISO 3310-1/2 (International Standard). You must ensure the supplier provides a Certificate of Compliance or a Calibration Certificate to guarantee that the wire cloth aperture and wire diameter meet these precise tolerances. For high-precision industries like pharmaceuticals, look for Inspection or Calibration grade sieves rather than standard Compliance grade.

How do I choose the right material for the sieve frame and mesh?

For most industrial and laboratory applications, 304 or 316 Stainless Steel is the gold standard due to its corrosion resistance and durability. If you are working with non-corrosive, dry aggregates, Brass frames may be a more economical choice, but they are softer and prone to deformation. Ensure the mesh is permanently attached to the frame, ideally using lead-free solder or a tensioned welding process to prevent material bypass.

What factors affect the accuracy and lifespan of a test sieve?

Accuracy is maintained through proper tensioning of the mesh; loose mesh leads to inaccurate particle sizing. Lifespan is extended by selecting the correct wire diameter for your specific material density. For abrasive materials, specify reinforced backing for fine meshes. Additionally, ensure the sieves feature a seamless frame design to prevent 'blind spots' where particles can get trapped, which causes cross-contamination.

How should I determine the appropriate sieve diameter and height for my application?

Common diameters include 8 inches (200mm) and 12 inches (300mm). Choose the diameter based on your sample volume to avoid overloading the mesh, which leads to poor separation. Height (Full vs. Half height) depends on your sieve shaker compatibility and the number of fractions you need to separate in a single stack. Full-height sieves allow more room for particle movement, while half-height sieves allow for taller stacks in limited shaker space.

Cross-Border Procurement & Risk Management for Precision Instruments

How can I mitigate the risk of receiving damaged or out-of-tolerance sieves?

Request a pre-shipment inspection (PSI) where the supplier uses a digital imaging system to verify aperture uniformity. Ensure the packaging includes individual protective boxes and moisture-proof desiccant, as even minor oxidation or physical dents during transit can render a precision sieve useless for certified laboratory work.

What are the best practices for negotiating with Chinese sieve manufacturers?

Focus on technical transparency rather than just price. Ask for the origin of the stainless steel wire and the specific weaving technology used. When ordering in bulk, negotiate for tiered pricing based on the complexity of the mesh (finer meshes are significantly more expensive). Always confirm if the quoted price includes traceable calibration reports from a third-party lab.

How should I handle shipping and customs for laboratory equipment?

Use HS Code 9604.00 (Hand sieves and hand riddles) for customs declaration. For international shipping, Air Freight is recommended for small sets to minimize vibration and handling damage. If using Sea Freight for large orders, ensure the pallets are ISPM 15 compliant and the sieves are vacuum-sealed to prevent salt-air corrosion during the voyage.

How do I ensure transaction security when sourcing from overseas?

Utilize secure payment methods and prioritize suppliers on Made-in-China.com who have undergone Audited Supplier verifications. This ensures the factory actually possesses the specialized weaving and calibration equipment required for precision instruments. Always use Trade Terms like FOB or FCA to maintain better control over the logistics chain and insurance.

Related queries