SourcingAI

Vortex flow sensor

I have found results from10000+products and8000+suppliers aboutVortex flow sensor

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Piezoelectric
Vortex Flow Meter
Type: Piezoresistive
Structure Type: Hot-Wire
Measuring Medium: Liquid
Output Signal Type: Digital Type
Production Process: Ceramics
Material: Stainless Steel
Accuracy Grade: 0.2G
IP Rating: IP68
Certification: ISO
Customized: Customized
Accuracy: >±1%
Main Application: Water
Sensor: Tube/Flange
Application: Industrial Production
Measuring Media: Gas
Measuring Principle: Mechanics
Measurement Object: Closed Pipeline
Size: DN50-100
Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control
Condition: New
Structure Type: Hot-Film
Structure Type: Measuring Core
Structure Type: Karman Vortex
Measuring Medium: Gas
Production Process: Integration
Production Process: Injection
Material: Plastic
Material: Ceramics
Material: Aluminum Alloy
Material: Metal
Accuracy Grade: 0.5G
Accuracy Grade: 1.0G
IP Rating: IP65
IP Rating: IP67
IP Rating: IP20
Certification: RoHS
Certification: JIS
Certification: DIN
Certification: ANS
Certification: GB
Certification: CE
Certification: ISO: 9001
Certification: CCC
Customized: Non-Customized
Accuracy: ±0.2-0.5%
Main Application: Nature Gas
Main Application: Wastewater
Main Application: Diesel Fuel
Main Application: Fuel Oil
Main Application: Corrosive Liquid/Gas
Sensor: Clamp-on/External
Sensor: Plug-in
Application: Energy Metering
Measuring Media: Liquid
Measuring Principle: Atomic Physics
Measuring Principle: Electrical Principles
Measurement Object: Open Channel
Size: DN5-10
Function: Protection

Sourcing guidance for Vortex Flow Sensor

What are the key technical specifications to consider when selecting a Vortex Flow Sensor for industrial use?

When sourcing a vortex flow sensor, you must prioritize measurement accuracy (typically ±1.0% for liquids and ±1.5% for gases/steam) and turndown ratio (ideally 10:1 or higher). Ensure the sensor body is made of 304 or 316 stainless steel to resist corrosion. Additionally, verify the Reynolds number range compatibility to ensure the sensor can accurately detect the Karman vortex street under your specific flow conditions.

How do I ensure the sensor is compatible with my existing control system?

Check for standard industrial output signals such as 4-20mA, pulse output, or RS485 (Modbus RTU). For advanced integration, look for units supporting HART protocol. It is also vital to confirm the power supply requirements (usually 12-24V DC) and whether the device supports digital displays for local monitoring.

What compliance standards are mandatory for vortex flow sensors in hazardous environments?

If the sensor is used in explosive atmospheres (e.g., oil and gas), it must have ExiaIICT6 or ExdIIBT6 explosion-proof certification. For international trade, ensure the supplier provides CE marking for the European market and ISO 9001 for manufacturing quality management. For steam applications, compliance with pressure vessel directives is often required.

What are the common usage scenarios and limitations of this technology?

Vortex flow sensors are ideal for saturated steam, superheated steam, compressed air, and low-viscosity liquids. However, they are not suitable for high-viscosity fluids or multi-phase flows (like liquid-gas mixtures). They also require a minimum flow velocity to generate detectable vortices; otherwise, the reading will be zero.

Cross-Border Procurement Strategy for Vortex Flow Sensors

What are the primary risks when purchasing precision instruments like flow sensors from overseas?

The main risks include damage during transit affecting calibration and technical mismatch. To mitigate this, require the supplier to use shock-absorbent packaging and provide a factory calibration certificate for every unit. Always verify the flange standard (ANSI, DIN, or JIS) before shipping to avoid installation failures.

How can I negotiate better terms with Chinese suppliers on Made-in-China.com?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for extended warranties (18-24 months) and request free spare parts (like replacement sensors or gaskets). For bulk orders, aim for a 15-20% discount by highlighting your potential for long-term partnership and repeat annual volume.

What shipping precautions should be taken for electronic flow meters?

Ensure the shipment is sent via air freight or express (DHL/FedEx) if the quantity is small, as prolonged sea freight exposure to humidity can affect sensitive electronics. Request vacuum-sealed plastic wrapping inside the wooden crates to prevent moisture ingress and oxidation of the circuit boards during cross-border transit.

How do I verify the credibility of a supplier on Made-in-China.com?

Look for 'Audited Suppliers' who have undergone on-site inspections by third-party agencies like SGS or Intertek. Check their export history specifically for flow meters and request video inspections of their testing laboratory to ensure they have the equipment to verify flow accuracy before the goods leave the factory.

Related queries