SourcingAI

Water tank level gauge

I have found results from70000+products and10000+suppliers aboutWater tank level gauge

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Float
Type: Submersible
Type: Digital Display
Lightning Protection Type
Contact: Contact
Output Signal Type: Switching Type
Production Process: Integration
Feature: Corrosion Resistant
Material: Plastic
IP Rating: IP67
Certification: CE
Customized: Customized
Range: >0-30m
Accuracy: 0.1%
Kind: Radar
All in One
Warranty: 1 Year
Process Temperature: -20℃~80℃
Generator Type: Diesel Generator
Measuring Range: Medium-pressure Gauge
Display: Digital
Application: Industrial
Connection Type: Radial Direction
Local Indication Type
Installation Structure: Convex
General Pressure Gauge
General Pressure Gauge
Measurement Accuracy: ±5mm
Principle: Magnetic Sensors
Surface Treatment: Painted
Range of Applications: Life
Structure Design: Flange Type
Pressure Range: High Pressure
Display Type: Decile Calibration
Accuracy Grade: 0.1G
Conditions of Use: Car Type
Usage: Common Units
AC Three Phase
Cooling Method: Water Cooling
Installation Method: Fixed
Contact: Contactless
Output Signal Type: Digital Type
Production Process: Normal Wirewound
Material: Stainless Steel
Material: Metal
Material: SS360L
Material: SS304
IP Rating: IP68
Certification: RoHS
Certification: ISO
Range: 0-30m
Range: 0-10m
Range: 0-3m
Accuracy: 0.1
Accuracy: 0.25%
Accuracy: 0.2%
Accuracy: 1%
Liquid Level Transmitter
Kind: Magnetic Flap
Kind: Glass
Kind: Float
Spring Pressure Gauge
Structure: Split Type
Process Temperature: -40~250℃
Process Temperature: -40~120℃
Process Temperature: -190~425℃
Function: Electric Signal-controlled
Measurement Accuracy: ±3mm
Measurement Accuracy: ±8mm
Range of Applications: Industrial
Conditions of Use: Trailer Type
Conditions of Use: Marine
Conditions of Use: Land Use

Sourcing guidance for Water Tank Level Gauge

What are the key technical specifications to consider when selecting a water tank level gauge?

Buyers must prioritize the measurement principle (Ultrasonic, Hydrostatic, Magnetic Float, or Capacitive) based on the liquid type. For clean water, ultrasonic sensors are preferred for non-contact measurement, while hydrostatic pressure sensors are ideal for deep tanks. Ensure the accuracy grade is ±0.5% FS or better and check the IP rating (IP65 for displays, IP68 for submersible sensors) to guarantee waterproof performance in humid environments.

How do I ensure the gauge is compatible with my existing industrial systems?

Verify the output signal type, such as 4-20mA, 0-10V, or RS485 (Modbus-RTU), to ensure seamless integration with PLC or SCADA systems. For remote monitoring, look for devices supporting LoRaWAN, NB-IoT, or Wi-Fi connectivity. Additionally, confirm the power supply requirements (typically 12-24V DC for industrial use or battery-powered for wireless models).

What material requirements are necessary for different water types?

For standard potable water, 304 stainless steel or food-grade plastics are sufficient. However, if the tank contains treated water with chemicals or brine, you must specify 316L stainless steel or PTFE-coated probes to prevent corrosion and ensure long-term structural integrity. Always request material analysis reports from the supplier.

What compliance standards should a professional water level gauge meet?

Ensure the product carries CE and RoHS certifications for international market entry. For drinking water applications, look for NSF/ANSI 61 or WRAS approval to ensure no harmful substances leach into the water. If the gauge is used in pressurized tanks, compliance with the Pressure Equipment Directive (PED) may be required.

Cross-Border Procurement & Risk Management for Level Gauges

How can I mitigate the risk of receiving inaccurate or faulty sensors?

Request a calibration certificate for each unit before shipment. It is highly recommended to use Made-in-China.com's Secured Trading services and hire a third-party inspection agency (like SGS or Intertek) to perform a functional test on a random sample from the batch to verify the linearity and hysteresis of the sensors.

What are the best practices for negotiating with Chinese sensor manufacturers?

Focus on long-term reliability rather than just the lowest price. Ask for the MTBF (Mean Time Between Failures) data. Negotiate a warranty period of at least 18-24 months, and clarify the replacement policy for defective units—specifically who covers the international return shipping costs.

What shipping precautions should be taken for sensitive electronic gauges?

Level gauges are precision instruments. Ensure the supplier uses anti-static packaging and shock-absorbent foam padding. For long-distance sea freight, specify the use of desiccant packs inside the inner packaging to prevent moisture condensation from damaging the internal circuitry during transit through different climate zones.

How do I handle customs and trade policy alignment for this category?

Confirm the correct HS Code (typically 9026.10) to determine accurate import duties. Be aware of anti-dumping duties or specific trade barriers in your country regarding electronic measuring instruments. Ensure all commercial invoices and packing lists clearly state the technical parameters to avoid delays during customs clearance.

Related queries