SourcingAI

Watt hour meter

I have found results from10000+products and5000+suppliers aboutWatt hour meter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Energy Meter
Type: Power Meter
Display: Digital
Installation: Direct Connected
Multi-Functional Energy Meter
Electric Equipment: Single-phase
Theory: Electronic Meter
Power Meter Connection: Feed-through Type
Measured Signal: Pulse Peak
Certification: ISO
Customized: Customized
Power: Electricity
Voltage Output: 380V
With LCD Display
AC and DC
DC Voltmeter Type: Electrostatic
AC Voltmeter Type: Electromagnetic
Display: Indicator
Usage: Watt-Hour Meter
Meter for Industry and Home Use
Standard Electric Energy Meter
Usage: Prepayment Meter
Reactive Energy Meter
Multi-rate Watt-hour Meters
Maximum Demand Meter
Electric Equipment: Three-phase Four-wire
Theory: Machine-electric Type
Theory: Static Meter
Theory: Electric Apparatus
Power Meter Connection: Terminal
Measured Signal: Continuous Wave
Certification: CE
Certification: RoHS
Certification: FDA
Certification: IAF
Certification: CCC
Customized: Non-Customized

Sourcing guidance for Watt Hour Meter

What are the key technical specifications to consider when selecting a Watt Hour Meter for industrial use?

When sourcing for industrial applications, prioritize Accuracy Class (typically Class 0.5s or 1.0 for billing purposes). Ensure the device supports the correct Current Rating (e.g., 5(60)A for direct connection or CT-operated for higher loads). Additionally, verify Communication Protocols such as RS485 Modbus-RTU, M-Bus, or DLMS/COSEM to ensure seamless integration with existing Energy Management Systems (EMS) or Building Automation Systems.

Which international compliance standards are mandatory for global trade of electricity meters?

Compliance is critical for legal metrology. For the European market, the MID (Measuring Instruments Directive) certification is mandatory. Globally, products should adhere to IEC 62053-21/22 for static meters. If exporting to North America, ANSI C12.20 standards are required. Always request Type Test Reports from accredited third-party labs like KEMA or TUV to verify performance under extreme temperatures and electromagnetic interference.

How do Smart Watt Hour Meters differ from traditional electronic meters in terms of functionality?

Smart Meters offer advanced features such as Bi-directional Metering (essential for solar PV integration), Time-of-Use (TOU) billing, and Remote Disconnect/Reconnect capabilities. They often include wireless modules like LoRaWAN, NB-IoT, or Wi-Fi for real-time data transmission, whereas traditional electronic meters only provide local LCD displays and basic pulse outputs.

What environmental factors impact the longevity and reliability of a Watt Hour Meter?

The Ingress Protection (IP) Rating is vital; for outdoor installation, a minimum of IP54 or IP65 is recommended to prevent dust and moisture entry. Furthermore, check the Operating Temperature Range (ideally -25°C to +70°C) and ensure the casing is made of Flame-retardant VO grade polycarbonate to prevent fire hazards during electrical faults.

Cross-Border Procurement Strategy for Energy Measurement Devices

What are the primary risks when importing Watt Hour Meters from overseas suppliers?

The biggest risk is Metrological Non-compliance, where the meter fails local utility accuracy tests, leading to customs rejection or legal penalties. To mitigate this, use Made-in-China.com’s Secured Trading services and insist on a Pre-shipment Inspection (PSI) by agencies like SGS to verify that the serial numbers and firmware versions match the certified prototypes.

How can buyers negotiate better terms with high-volume meter manufacturers?

Focus on Tiered Pricing based on annual volume rather than single orders. Negotiate for Customized Branding (OEM) and Firmware Localization (language and currency settings) included in the unit price. For large-scale projects, request a 2-5% buffer of spare units instead of a cash discount to cover potential field failures without delaying project timelines.

What logistics precautions should be taken for sensitive electronic measuring equipment?

Watt Hour Meters contain sensitive shunts and electronic components. Ensure the supplier uses Anti-static packaging and Shock-absorbent foam inserts. For sea freight, specify the use of Desiccant silica gel packs inside the master cartons to prevent humidity-induced PCB corrosion during long transit times through tropical zones.

How to ensure transaction security and quality assurance when sourcing from China?

Prioritize Audited Suppliers on Made-in-China.com who possess ISO 9001 and ISO 14001 certifications. Utilize Trade Terms like CIF or DAP to clearly define risk transfer points. Always use Escrow-based payment methods where funds are only released to the supplier after the buyer confirms receipt of goods and successful initial functional testing.

Related queries