SourcingAI

Weighing balance scale

I have found results from50000+products and20000+suppliers aboutWeighing balance scale

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Accuracy: 1g
Display Type: LCD
Location: Desktop Scale
Material: Plastic
Measure Method: Automatic
Application: Industrial Scales
Function: Weighing Scale
Structure: Electronic Scale
Shape: Square
Graduation Value: ≤5k
Functional Classification: Measure Mass
Special Definition Code
Weighing: 30-300kg
Applicable Crowd: Adult
Weight Range: 8kg-200kg
Certification: CE
Color: White
Maximum Weighing: 300-500kg
Usage: General Balance
Power Source: Battery
Material of Tweezers: Stainless Steel
Suitable for: Boothroom
Screen Printing Color
Power: Battery
Customized: Non-Customized
Accuracy: III
Accuracy: 0.1kg
Accuracy: 0.01g
Accuracy: 1kg
Accuracy: 0.0001g
Accuracy: 0.001g
Display Type: LED
Display Type: Mechanical Hand
Location: Platform Scale
Material: Stainless Steel
Material: Iron
Material: Carbon Steel
Application: Commercial Scale
Application: Special Scales
Application: Industry
Application: School
Application: Hospital
Application: Lab
Function: Counting Scales
Function: Body Weight
Function: Body Fat
Function: Calories
Function: Hydration
Electronic Platform Scale
Mechanical and Electronic Scale
Mechanical and Electrical Scale
Structure: Mechanical Scale
Structure: Portable
Shape: Circular
Shape: Rectangular
Shape: Oval
Shape: Polygon
Functional Classification: Measure Weight
Functional Classification: Measure Price
Number System: Binary Code
Number System: ASCII Code
Weighing: >300kg
Weighing: <30kg
Applicable Crowd: Baby
Weight Range: 1kg-20kg
Certification: ISO
Certification: RoHS
Test of Balance
Usage: Precision Balance
Usage: Analytical Balance
Appearance: Transpatent Glass

Sourcing guidance for Weighing Balance Scale

What are the key technical specifications to consider when selecting a professional weighing balance?

Buyers must prioritize Readability (d) and Repeatability (Standard Deviation). For laboratory use, an Analytical Balance typically requires a readability of 0.1mg or 0.01mg, while Precision Balances may range from 0.001g to 0.1g. Ensure the device features Internal Calibration (Auto-Cal) to maintain accuracy against temperature fluctuations, and check for Load Cell quality, preferably utilizing Electromagnetic Force Restoration (EMFR) technology for high-precision requirements.

Which international compliance standards are mandatory for weighing scales in commercial and medical sectors?

For commercial transactions (Legal-for-Trade), the scale must have OIML (International Organization of Legal Metrology) certification or NTEP (National Type Evaluation Program) approval for the US market. In medical or pharmaceutical environments, compliance with ISO 13485 and FDA standards is essential. Additionally, ensure the product carries the CE mark and complies with the RoHS Directive for electronic safety and environmental protection.

How do usage scenarios dictate the choice of scale material and IP rating?

In food processing or chemical industries, a minimum of IP65 or IP67 rating is required to ensure the device is waterproof and dustproof. The housing and weighing pan should be constructed from 304 or 316 Stainless Steel to prevent corrosion and facilitate easy sanitization. For static-sensitive laboratory environments, an Anti-static glass draft shield is necessary to prevent measurement drift.

What integration capabilities should modern digital balances offer for B2B operations?

To support Industry 4.0 and smart warehousing, look for scales equipped with RS232, USB, or Ethernet (RJ45) interfaces. Advanced models offer Bluetooth or Wi-Fi connectivity for direct data transmission to ERP or LIMS (Laboratory Information Management Systems). Ensure the supplier provides SDKs or communication protocols to facilitate seamless software integration.

Cross-Border Procurement & Risk Management for Weighing Equipment

How can I mitigate the risk of damage during international transit?

Precision balances are highly sensitive to vibration. Insist that the supplier uses Double-walled Corrugated Boxes with Customized EPE Foam inserts. Crucially, ensure the Shipping Lock (Transportation Bolt) is engaged to protect the load cell from mechanical shock. For high-value analytical balances, consider Vacuum Packaging to prevent moisture ingress during sea freight.

What is the most effective strategy for negotiating with weighing scale manufacturers on Made-in-China.com?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for extended warranties (24-36 months) and the inclusion of Calibration Weights (Class E2 or F1) as part of the bundle. Request a Video Factory Audit to verify their testing laboratory and QC process, and ask for tiered pricing based on annual procurement volume rather than a single spot order.

How do I handle customs clearance and 'Legal-for-Trade' restrictions in my country?

Before shipping, verify the HS Code (typically 8423) and check if your local government requires a Pattern Approval Certificate. Some countries mandate that scales be sealed and verified by a local weights and measures official upon arrival. Work with a supplier on Made-in-China.com who can provide a Certificate of Origin to benefit from preferential tariff rates under trade agreements like RCEP or FTA.

What transaction security measures should be taken for large-scale orders?

Utilize Secured Payment services provided by the platform to ensure funds are only released upon confirmation of shipment. For bulk orders, hire a Third-Party Inspection (TPI) agency (like SGS or Intertek) to perform a Pre-Shipment Inspection (PSI). This inspection should include a Repeatability Test and a Corner Load Test to ensure every unit meets the agreed-upon technical specifications before leaving the factory.

Related queries