Capacity

Sample price:US$167.31/piece.Request sample

Product profile

Customization

Available

Phase

1-10kVA 1/1; 15-20kVA 3/1

Type

On-line

Model NO.

3C15KS; C Series 1-20kVA

Protection

Protection Per Selected Model

Application

Business System Backup

Classification

Online Double Conversion UPS

Standby Time

K Internal; Ks External Batteries

Standby UPS

Online Sine Wave UPS

Output Capacity

1-20kVA by Model

Equipment Mode

Tower Cabinet; Model-Specific

Brand

Feixiangda

Output Waveform

Sine Wave; Load Compatibility Must Be Checked

Topology

Online Double Conversion; Mains-to-Battery 0ms

Input Voltage Range

Depends on Model and Voltage Version

Isolation Transformer

No Built-in Isolation Transformer

Output Voltage Flexibility

Voltage Version and Connectors by Selected Model

Frequency Compatibility

50/60Hz; Conversion Function by Confirmed Order

Output Power Factor

0.9; Rated Kw = Rated kVA X 0.9

Overload Capacity

Model-Specific; Verify Starting and Peak Load

Battery Management

K Internal; Ks External; Runtime by Load

Communication Interfaces

RS232/Network/Dry Contacts/Modbus by Configuration

Operating Temperature

Site Conditions to Match Selected Model Manual

Generator Compatible

Generator Matching Requires Project Review

Cold Start

Battery Start Per Selected Model Manual

Certifications

Model-Specific Compliance Documents on Request

Warranty & Support

UPS Warranty 1 Year; Service Terms by Order

Transport Package

Carton with Foam; Packing by Selected Model

Specification

1-20kVA; dimensions by exact model

Trademark

Customizable

Origin

China

HS Code

8504402000

Production Capacity

5000

Key features

Online Double Conversion: Sine-wave output with 0ms mains-to-battery transfer in normal online operation. Bypass switching is specified separately.
Featured Model 3C15KS: 15kVA / 13.5kW. Selected for Business System Backup. Other 1-20kVA series configurations are listed separately.
Output Power Factor 0.9: Rated outputs are 0.9, 1.8, 2.7, 5.4, 9, 13.5 and 18kW for the listed capacities respectively.
Input Phase Selection: 1-10kVA models are single-phase input/output. 3C15KS and 3C20KS are three-phase input, single-phase output.
Battery Options: K models have internal batteries. KS long-backup models use external battery banks selected for load, runtime and charger compatibility.
Office and IT Backup: Suitable for correctly sized computers, workstations, routers, network switches, security equipment and bank IT loads.
Home Work and Gaming: Match the PC, display and network load to the UPS rating and required backup time. High-surge appliances require separate review.
No Built-in Isolation Transformer: Ordinary C-series models provide sine-wave output without a built-in isolation transformer.
Connections by Model: Output sockets, terminals, battery connections and optional RS232/USB/RS485/SNMP monitoring are confirmed for the selected model and order.
Factory Supply: Branding, packaging and project configurations can be agreed by order. UPS warranty is 1 year.

Company profile

Shenzhen Feixiangda Electronic Co., Ltd.
High Repeat Buyers ChoiceLow MOQ100% Finished Products InspectionProduct Certification
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 19 Years CertifiedNearest Port: Shenzhen PortAverage Response Time: ≤0.04h

About Our Factory & Business Background

AddressBuilding 2, No. 49, Fenghuang 2nd Road, Humen Town, Dongguan, Guangdong, China
Plant Area5000 square meters
Number of Employees59
Registered Capital5,000,000 RMB
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity1 Piece
Supply Chain Partners12

Our Production Capability & Technical Expertise

Main ProductsLow Frequency UPS, High Frequency UPS, AC Voltage Stabilizer AVR, Dry Type Transformer, Stabilizer Transformer Integrated Unit, Variable Frequency Power Supply, Voltage Regulator, Oil Immersed Voltage Stabilizer
Production Lines4
Production MachinesCutter, Bending Machine, Welding machine, Winding machine
QA/QC inspectors2 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instruction but no written records
R&D Engineers3 people
Traceability of Raw MaterialsNo
Own BrandYes

Our Industry Experience & Global Business Record

Year of Establishment2006-12-12
Main MarketsDomestic
Repeat Buyers Choice50%~80%
Number of Foreign Trading Staff4
Overseas Agent/BranchNo
New Products Launched in Last yearYes

Our Certifications, Standards & Industry Recognition

Product CertificationCE
Cooperated with Fortune 500No

Product Q&A

Q:What type of UPS is this?
A:
This is an online double-conversion C-series UPS with sine-wave output. Normal online mains/battery transfer is 0ms. Ordinary models in this listing have no built-in isolation transformer.
Q:How do I select an online UPS for business system backup?
A:
The featured 3C15KS is rated 15kVA / 13.5kW. List the connected equipment in both kW and kVA, including peak demand and planned expansion. Confirm supply phase, voltage, connectors and backup duration before selecting a UPS and battery configuration.
Q:What is the difference between K and KS models?
A:
K standard models contain internal batteries. KS long-backup models use external batteries matched to the load and required runtime. The two versions have different weights and may have different cabinet dimensions.
Q:Can a standard model also use external batteries?
A:
Our compatible standard models can retain their internal batteries and add a matched external bank. Confirm the exact UPS model, DC voltage, battery type, charger capacity, connectors and protection before selecting the bank.
Q:How do 10kVA, 15kVA and 20kVA versions differ?
A:
C10K and C10KS use single-phase input and output. The confirmed 15kVA and 20kVA versions are 3C15KS and 3C20KS, with three-phase input and single-phase output and external batteries. C10K in this listing is the C10K-LCD-B16 internal-battery version.