Powered by Made-in-China.com

Fire Detection Tube Suppression Systems Using Heat-Sensitive Detection Tubes
US$130.00-3,000.00
1 Set
Product profile
Customization
AvailableFire Agent
Fk-5-1-12 / Hfc-227ea / CO2System Type
Direct ReleaseModel NO.
SNG21-06A, SNG21-06B, SNG21-06CActivation
Heat-Sensitive Detection TubeDischarge Method
Through Detection Tube OpeningTube Outer Diameter
6 mmTube Inner Diameter
4 mmNominal Actuation
170 +/- 10 C; Options 100/120/140 CTransport Package
Wooden CaseSpecification
FK/HFC: 1-9 kg; CO2: 2, 6, 10 kgTrademark
SYNERGYOrigin
ChinaHS Code
8424100090Production Capacity
3000 Sets/MonthKey features
Direct Release Mechanism: Detection tube ruptures to trigger agent discharge directly at fire source.
Multiple Agent Options: Available with FK-5-1-12, HFC-227ea, or CO2 tailored to specific hazards.
Flexible Charge Sizes: Clean agents range 1-9 kg; CO2 options available in 2, 6, and 10 kg.
Customizable Alarms: Optional pressure signal devices and audiovisual alarms for specific needs.
Compact Design: Ideal for safeguarding electrical cabinets and equipment enclosures.
Variable Activation Temp: Nominal 170 +/- 10 C with options at 100, 120, and 140 C.
Low Minimum Order: Minimum order quantity is just 1 set for flexible purchasing.
Fast Production Capacity: Capable of producing 3,000 sets per month to meet high demand.
Company profile
Business Type: Manufacturer/Factory CertifiedR&D Capacity: ODM Service AvailableExport Year: 2003-03-01 CertifiedNearest Port: Tianjin Port, Ningbo Port, Shanghai Port, Qingdao PortAverage Response Time: ≤10.72h CertifiedTerms of Payment: LC, T/T
AI-Powered supplier vetting
SummaryThe supplier is identified as a trading company rather than an offshore company or professional technical supplier. It offers broad customization and ODM services, but reports no 3D software design service, no new products in the past year, no SDK, and no OEM service for popular brands. After-sales support includes debugging, maintenance, repair, training, and equipment installation, with overseas service coverage listed in seven countries, although it has no overseas branches, agents, warehouse, or showroom. Service-control procedures and corrective-action records are documented, while the approved-supplier list lacks approval signatures or dates. ISO9001:2015 and CE-related certification capability are reported. Financial credibility cannot be confirmed because the provided financial indicators are all stated as zero. Production outsourcing procedures, contracts, and in-stock capability are either unknown or unavailable.
CertificationsThe supplier reports an ISO9001:2015 certificate and lists CE among its product certification capabilities. The slices do not provide certificate validity, scope, issuing body, or expiry details.
After-Sales capabilityAfter-sales offerings include debugging, maintenance, repair, training, and equipment installation, supported by listed overseas service countries and participation in Interschutz 2026. However, the supplier has no overseas agents or branches, warehouse, or showroom, so service delivery infrastructure is partly limited.
R&D capabilityThe supplier provides ODM services and multiple forms of customization, but reports no new products in the past year, no SDK, no 3D software design service, and no professional technical R&D capability. This indicates service-based design flexibility but limited demonstrated innovation infrastructure.
Customization capabilityThe supplier explicitly offers customization from samples, designs, full customization, minor customization, flexible customization, and ODM services. These statements directly support a broad customization offering despite the absence of 3D software design services.
Product Q&A
Q:How does a direct release fire detection tube system work?
A:
The system features a heat-sensitive tube strategically placed near potential fire sources. Upon exposure to sufficient heat, the tube bursts, triggering the system to discharge the extinguishing agent directly through the tube's opening.
Q:Can one system be filled with any of the three agents?
A:
No. Each agent requires a specific model: SNG21-06A for FK-5-1-12, SNG21-06B for HFC-227ea, or SNG21-06C for CO2. The cylinders, valves, and tubing must align with the agent and its pressure specifications; different agents cannot be interchanged within an installed configuration.
Q:Is a separate discharge nozzle required?
A:
The direct release configuration involves discharging through the detection tube's opening. For systems requiring a separate nozzle and discharge line, opt for the indirect release model.
Q:What agent charge sizes are available?
A:
Direct models for FK-5-1-12 and HFC-227ea offer charges of 1, 2, 3, 4, 6, and 9 kg, while CO2 direct models provide charges of 2, 6, and 10 kg. These measurements represent the agent's mass, not the cylinder's volume.
Q:What are the dimensions and activation temperature specifications for the detection tube?
A:
The versatile detection tube boasts a sleek 6 mm outside diameter and a 4 mm inside diameter, engineered for precision. It features a nominal actuation temperature of 170 +/- 10 degrees Celsius, ensuring reliable performance. For specific needs, tube options are available at 100, 120, and 140 degrees Celsius, depending on the selected configuration, allowing flexibility to suit any installation requirement.
Send Inquiry
*To:
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.*Content:
Supplier replies will be sent to your registered email
You may also like
Indirect Release Fire Trace Tube Fire Suppression System with Nozzles
US$130.00-3,000.00
1 Set(MOQ)
Advanced Direct Release Fire Trace Tube Fire Suppression System for Electrical Cabinets
US$130.00-3,000.00
1 Set(MOQ)
FM200 Hfc-227ea Tube Fire Suppression System for Sensitive Electronics
US$77.00-80.00
100 Sets(MOQ)
Direct Release Fire Detection Tube Suppression Systems for Fire Protection
US$130.00-3,000.00
1 Set(MOQ)
Fire Detection Tube Suppression Systems with Direct Release Activation
US$130.00-3,000.00
1 Set(MOQ)
Automatic Tube Fire Suppression System for Electrical Devices
US$45.00-48.00
100 Sets(MOQ)
Detection Tube Automatic Gas Fire Extinguishing System
US$45.00-48.00
100 Sets(MOQ)
Vehicle Engine Bay Automatic Fire Suppression System Afff Foam Based Auto Fire Control System with Heat Smoke Sensor
US$2,890.00-3,860.00
3 Sets(MOQ)
Od8*6mm 170° Red PVC Fire Detection Tube Fire Trace System
US$5.10
5,000 Pieces(MOQ)
High Quality Dry Powder Fire Extinguishing System for Fire Suppression
US$1.00-20,000.00
1 Set(MOQ)
Hfc-227ea FM-200 Cabinet Type Fire Suppression System
US$100.00-10,000.00
1 Piece(MOQ)
Fire Suppression System, FM 200
Negotiable
1 Piece(MOQ)
Gas Fire Suppression Automatic Pressure Relief System
US$17.90-19.90
99 Pieces(MOQ)
Automatic Tracking Positioning Water Jet Fire Suppression System
US$100.00-10,000.00
1 Piece(MOQ)
CO2 High Pressure Fire Suppression System
Negotiable
1 Set(MOQ)
Fire Suppression System Pressure Relief Damper 360X360mm
US$17.90-19.90
99 Pieces(MOQ)
Compressed Air Foam Fire Suppression System
US$100.00-10,000.00
1 Piece(MOQ)
Water Mist Foam Fire Suppression System
US$100.00-10,000.00
1 Piece(MOQ)