Product Attributes:
Type: Energy Meter
Resistance Box, Meter Box
Installation: Direct Connected
Accuracy: 0.5
Kind: Thermocouple Type
Power Source: AC Meter
Theory: Electronic Meter
Display Ammeter Type: Three-phase Digital
Customized: Customized
Display: Digital
Application: Electronic Equipment
Multi-Functional Energy Meter
Electric Equipment: Three-phase Four-wire
Power Meter Connection: Terminal
Measured Signal: Pulse Peak
Certification: ISO
Display Type: LED
Cooling Purpose: Production
Control Method: Electronic Type
Bulb Type: LED
DC Voltmeter Type: Electrostatic
AC Voltmeter Type: Electric
Task: Following
Condition: New
Material: Steel
Structure: Wall Mounted
Warranty: 1 Year
Protection Level: IP67
Voltage: 220V
Rated Load: 800~1000kg
Surface Treatment: Powder Coating
Emitting Color: Red
IP Rating: IP65
Lamp Body Material: ABS
General Installation Meter
Accuracy: 1
Kind: Rotating Coil
Rotating Iron Chip
AC and DC
Power Source: AC
Power Source: DC
Theory: Machine-electric Type
Theory: Static Meter
Theory: Electric Apparatus
Display Ammeter Type: Single-phase Digital
Customized: Non-Customized
Application: Electric Power
Application: Industrial
Usage: Watt-Hour Meter
Standard Electric Energy Meter
Meter for Industry and Home Use
Electric Equipment: Single-phase
Power Meter Connection: Feed-through Type
Measured Signal: Continuous Wave
Certification: CE
Certification: RoHS
Certification: CCC

Sourcing guidance for Digital Ammeter

What are the key technical specifications to consider when selecting a digital ammeter for industrial use?

When sourcing digital ammeters, you must prioritize Measurement Accuracy (typically Class 0.5 or 0.2 for industrial grade) and Input Range. Ensure the device supports the required AC/DC current types and check if it requires an External Shunt or Current Transformer (CT) for high-current measurements. Additionally, verify the Sampling Rate (e.g., ≥3 times/second) to ensure real-time monitoring stability.

Which international compliance standards are mandatory for digital ammeters in cross-border trade?

For the European market, CE Marking and RoHS compliance are essential to ensure electromagnetic compatibility and environmental safety. For North America, look for UL or ETL certification. Crucially, the device should meet IEC 61010-1 safety requirements for electrical equipment for measurement, control, and laboratory use to prevent high-voltage hazards.

How does the display technology and integration capability affect the procurement choice?

Buyers should choose between LED displays (better for low-light industrial environments) and LCD displays (lower power consumption, more data fields). For smart factory integration, ensure the ammeter supports RS485 Modbus-RTU communication protocols, allowing it to transmit data directly to PLC or SCADA systems for centralized monitoring.

What environmental durability factors should be verified for harsh operating conditions?

If the ammeter is used in outdoor cabinets or dusty factories, verify the IP Rating (e.g., IP65 for the front panel). Check the Operating Temperature Range (standard is -10°C to +55°C) and Flame Retardancy of the casing material, typically requiring UL94-V0 grade plastic to ensure fire safety.

Cross-Border Procurement & Risk Management for Digital Ammeters

How can I mitigate the risk of receiving substandard electrical components?

Always request a Pre-shipment Inspection (PSI) and ask the supplier to provide a Calibration Certificate for a random sample from your batch. On Made-in-China.com, prioritize Audited Suppliers who have undergone third-party onsite verification of their manufacturing facilities and quality management systems.

What are the best strategies for negotiating with digital instrument suppliers?

Focus on Long-term Technical Support and Warranty Terms (aim for at least 24 months) rather than just the unit price. For bulk orders, negotiate for Customized Branding (OEM) and request a 1-2% spare parts allowance to cover potential defects during installation without needing international returns.

What should be considered regarding international shipping and customs for sensitive electronics?

Digital ammeters are sensitive to Electrostatic Discharge (ESD) and mechanical shock. Ensure the supplier uses Anti-static packaging and robust cushioning. For customs, ensure the HS Code (typically 9030.33) is correctly declared to avoid tariff disputes, and confirm if the destination country requires specific Energy Efficiency labels.

How to ensure transaction security when dealing with high-value industrial orders?

Utilize Secured Payment Services provided by reputable platforms like Made-in-China.com to ensure funds are only released after the goods have been shipped and verified. Avoid direct wire transfers to private accounts; always use Corporate Accounts that match the supplier's registered business name.