SourcingAI

Emergency led light

I have found results from70000+products and20000+suppliers aboutEmergency led light

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Driveway Traffic Light
Efficient-Mirror Tri-proof Light
Warning Traffic Light
Bulb Type: LED
Certification: CE
Housing Material: ABS
IP Rating: IP67
Application: Road Construction
Function: Yellow Signal
Light Source: LED
Patterns: Circle
Battery Type: Ni-Cd
Beam Angle: <10Deg
Color Temperature: Cool White
Ip Rating: IP67
> 5,000 Lumens
Feature: Waterproof
Usage: Mine
Lifespan: ≥50000H
Brightness Levels: Ultra Bright
Crust Color: Red
Lighting Modes: Lantern
Power Source: Rechargeable Battery
Emitting Color: Red
Power: 21-30W
Cold Rolled Steel Sheet
Lamp Body Material: Aluminum Alloy
Irradiated Area: ≥30m²
Input Voltage: 220v
LED Chips Brand: Osram
Voltage: 12V
Voltage Type: DC
LED Type: SMD 3528
Emergency Time: 3-4h
Operation Mode: Non-maintained
LED: High-power
Light: Gradual Changing
Warranty: 2 Years
Certification: RoHS
Certification: CCC
Certification: ETL
Certification: FCC
Certification: SAA
Certification: CREE
IP Rating: IP66
IP Rating: IP44
IP Rating: IP65
IP Rating: IP33
IP Rating: IP68
Application: Parking Lot
Application: Tunnel
Application: Road
Application: General
Function: Red Signal
Flash Alarm Signals
Traffic Signal Wand
Function: Green Signal
Battery Type: Lead-acid
Battery Type: Ni-Cd Battery
Color Temperature: Pure White
Color Temperature: Warm White
Feature: Anti-corrosion
Feature: Dust-Proof
Usage: Gymnasium
Usage: Shipyard
Usage: Exhibition
Usage: Warehouse
Usage: Shopping Mall
Usage: Factory
Usage: Tunnel
Usage: Spot Lighting
Usage: Landscape Accent
Emitting Color: White
Emitting Color: Cool White
Power: ≤5W
Power: 51-80W
Material: Plastic
LED Chips Brand: Semileds
Operation Mode: Maintained

Sourcing guidance for Emergency LED Light

What are the key technical specifications to consider when sourcing Emergency LED Lights for commercial use?

Buyers should prioritize Battery Chemistry (LiFePO4 is preferred over Ni-Cd for longer life cycles), Luminous Flux (minimum 300 lumens for high-ceiling areas), and Emergency Duration (standard requirement is usually ≥90 minutes or 180 minutes depending on local fire codes). Additionally, ensure the IP Rating is at least IP65 if the units are intended for outdoor or industrial environments to prevent dust and water ingress.

Which international compliance standards are mandatory for Emergency LED Lights?

For the North American market, UL 924 certification is essential for emergency lighting and power equipment. For the European market, products must adhere to EN 60598-2-22 and carry the CE-LVD and CE-EMC marks. Furthermore, ensure the manufacturer complies with RoHS to guarantee the absence of hazardous substances in the electronic components.

How can I verify the reliability of the 'Auto-Test' function in these products?

The Self-Diagnostic (Auto-Test) function is a critical safety feature that automatically performs monthly and annual discharge tests. You should request test reports from the supplier that demonstrate the system's ability to signal failures via LED indicators (e.g., battery fault, lamp fault, or charger fault). High-quality suppliers on Made-in-China.com often provide video demonstrations of these diagnostic sequences.

What are the usage scenarios and installation requirements for different types of emergency lights?

Emergency lights are categorized into Maintained (always on) and Non-Maintained (on only during power failure). For Exit Signs, high visibility and uniform luminance are required. Installation should consider mounting height and spacing to ensure a minimum of 1 lux along the center line of the escape route, as per international fire safety guidelines.

Cross-Border Procurement Strategy & Risk Management

What are the specific risks associated with shipping Emergency LED Lights internationally?

The primary risk involves the Lithium batteries, which are classified as Class 9 Dangerous Goods. You must ensure the supplier provides a valid UN38.3 Test Report and an MSDS (Material Safety Data Sheet). Failure to provide these will lead to customs seizures or refusal by airlines/shipping lines. Always confirm if the supplier has experience in DG (Dangerous Goods) packaging.

How should I negotiate quality assurance and warranty terms with B2B suppliers?

Negotiate a warranty period of at least 3 to 5 years, specifically covering the battery capacity. Demand a 0.5% to 1% spare parts allowance for large orders to cover potential DOA (Dead on Arrival) units. Use Made-in-China.com's Secured Trading services to ensure that payment is only released after the goods pass a pre-shipment inspection (PSI) by a third party like SGS or Intertek.

What is the most cost-effective shipping method for bulk emergency lighting orders to the US or Europe?

For large volumes, Sea Freight (FCL or LCL) is the most economical. However, due to the battery content, you should request DDP (Delivered Duty Paid) terms if you want the supplier to handle the complex customs clearance and 'Dangerous Goods' surcharges. For smaller trial orders, specialized battery couriers (like FedEx/UPS DG service) are necessary, though they carry higher freight costs.

How can I verify a supplier's manufacturing capability before placing a large order?

Check the supplier's Audit Reports on Made-in-China.com to verify their factory size, production lines, and ISO 9001 certification. Request a factory walk-through via video call to inspect their integrating sphere (for light testing) and aging test racks, where lights should be tested for at least 24-48 hours before packing.

Related queries