SourcingAI

Slurry density meter

I have found results from10000+products and2000+suppliers aboutSlurry density meter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Concentration Meter
Fluid Oscillation Flow Meter
Coriolis Mass Flow Meter
Electromagnetic Flow Meter
Display: Digital
Appliance: Food Analysis
Portable: Portable
Certification: ISO9001
Maximum Measurement Range: ≥6D
Transmission-type Density Meter
Viscometer Type: Capillary
Float-type Density Meter
Test Density: Heavy
Viscometer Reproducibility: ±0.2%
Viscometer Rotor Number: 6
Viscometer Rotor Speed: 60r/min
Viscometer Rotor Specifications: 0 Size
Accuracy: ±0.6-1%
Main Application: Water
Size: DN100-500
Sensor: Plug-in
Application: Energy Metering
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Structure: Open Frame
Form: Partly-welded Type
Operation Voltage: High Voltage
Application Range: High-rise Buildings
Shell Material: Stainless Steel
Method: Chemical Treatment
Usage: Industrial
Appliance: Medical Research
Appliance: Biochemistry
Portable: Non Portable
Certification: CE
Certification: RoHS
Certification: ISO
Maximum Measurement Range: 4D-5D
Viscometer Type: Rotary
Viscometer Type: Vibration
Vibrating Density Meter
Test Density: Light
Viscometer Reproducibility: ±0.5%
Viscometer Rotor Number: 1
Viscometer Rotor Speed: 12r/min
Viscometer Rotor Speed: 6r/min
Viscometer Rotor Specifications: 1 Size
Accuracy: ± 1.5%
Accuracy: ±0.2-0.5%
Main Application: Wastewater
Main Application: Diesel Fuel
Main Application: Fuel Oil
Main Application: Nature Gas
Main Application: Corrosive Liquid/Gas
Size: 3 Uint
Sensor: Tube/Flange
Application: Industrial Production
Application: Environmental Protection

Sourcing guidance for Slurry Density Meter

What are the key measurement technologies for Slurry Density Meters and how do I choose between them?

The choice depends on the slurry composition and environmental constraints. Tuning Fork (Vibration) technology is highly accurate for homogeneous liquids but may struggle with high-viscosity or aerated slurries. Ultrasonic meters are non-intrusive and ideal for abrasive slurries as they have no moving parts, though they require stable flow. Radioactive (Nuclear) density meters provide the highest precision for extremely thick or hazardous slurries without pipe penetration, but require strict regulatory compliance and specialized handling licenses. For most industrial mineral processing, Coriolis mass flow meters are preferred for providing simultaneous density and mass flow data.

What material specifications are critical for ensuring the longevity of the meter in abrasive environments?

Since slurries often contain solid particles (mining, dredging, or cement), the wetted parts must be wear-resistant. Ensure the sensor probe or lining is made of 316L Stainless Steel, Hastelloy, or Tungsten Carbide coating. For highly corrosive chemical slurries, PTFE (Teflon) or PFA linings are essential. Always verify the IP67 or IP68 ingress protection rating to ensure the electronics are sealed against moisture and dust in harsh industrial settings.

How do I ensure the technical compatibility of the meter with my existing control systems?

Confirm that the device supports standard industrial communication protocols. Most modern systems require a 4-20mA analog output with HART protocol for remote configuration. For advanced automation, check for Modbus RS485, Profibus, or Foundation Fieldbus compatibility. Additionally, ensure the power supply requirements (typically 24V DC or 220V AC) match your facility's infrastructure to avoid additional transformer costs.

What are the essential compliance standards and certifications for international procurement?

For safety and quality assurance, the supplier should provide ISO 9001 certification. If the meter is used in hazardous or explosive environments (like oil & gas or chemical plants), ATEX, IECEx, or UL explosion-proof certifications are mandatory. For European markets, the CE mark is required, ensuring compliance with EMC (Electromagnetic Compatibility) and LVD (Low Voltage Directive) standards.

Cross-Border Procurement Strategy for Industrial Instrumentation

How can I mitigate the risks of purchasing high-precision instruments from overseas suppliers?

Request a Factory Acceptance Test (FAT) report and a calibration certificate traceable to international standards (like NIST or DKD) before shipment. Use Made-in-China.com's Secured Trading services to ensure payment is only released upon proof of shipping and document verification. For high-value orders, consider hiring a third-party inspection agency (e.g., SGS or BV) to verify the product's technical specs at the manufacturer's site.

What are the best practices for negotiating with Slurry Density Meter manufacturers?

Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for a longer warranty period (standard is 12 months, aim for 24 months) and the inclusion of essential spare parts (like gaskets or replacement probes). Ask for volume discounts if you plan to standardize your facility with one brand; typical discounts range from 10-20% for orders exceeding 5 units.

What should be considered regarding international shipping and customs for sensitive electronics?

Slurry density meters contain sensitive sensors that can be damaged by vibration or static. Insist on anti-static vacuum packaging and reinforced wooden crates (IPPC certified). If the meter uses a radioactive source, be aware that shipping is highly restricted and requires specialized Class 7 dangerous goods logistics, which significantly increases costs and lead times. For standard electronic meters, DDP (Delivered Duty Paid) terms are recommended for buyers who want the supplier to handle all import complexities.

Related queries